Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 10 de 10
Filter
Add filters








Year range
1.
The Journal of Advanced Prosthodontics ; : 155-170, 2023.
Article in English | WPRIM | ID: wpr-1002873

ABSTRACT

PURPOSE@#. This study aims to clinically compare the fitness and trueness of zirconia crowns fabricated by different combinations of open CAD-CAM systems. @*MATERIALS AND METHODS@#. Total of 40 patients were enrolled in this study, and 9 different zirconia crowns were prepared per patient. Each crown was made through the cross-application of 3 different design software (EZIS VR, 3Shape Dental System, Exocad) with 3 different processing devices (Aegis HM, Trione Z, Motion 2). The marginal gap, absolute marginal discrepancy, internal gap(axial, line angle, occlusal) by a silicone replica technique were measured to compare the fit of the crown. The scanned inner and outer surfaces of the crowns were compared to CAD data using 3D metrology software to evaluate trueness. @*RESULTS@#. There were significant differences in the marginal gap, absolute marginal discrepancy, axial and line angle internal gap among the groups (P .05). @*CONCLUSION@#. All 9 groups showed clinically acceptable level of marginal gaps ranging from 74.26 to 112.20 μm in terms of fit comparison. In the comparison of trueness, no significant difference within each group was spotted. Within the limitation of this study, open CAD-CAM systems used in this study can be assembled properly to fabricate zirconia crown. [J Adv Prosthodont 2023;15:155-70]

2.
The Journal of Advanced Prosthodontics ; : 202-213, 2023.
Article in English | WPRIM | ID: wpr-1002869

ABSTRACT

PURPOSE@#This prospective clinical study was conducted to evaluate the clinical usefulness of the freely detachable zirconia ball- and spring-retained implant prosthesis (BSRP) through a comparative analysis of screw- and cement-retained implant prosthesis (SCRP). @*MATERIALS AND METHODS@#A multi-center, randomized, prospective clinical study evaluating the clinical usefulness of the detachable zirconia ball- and spring-retained implant prostheses was conducted. Sixty-four implant prostheses in 64 patients were examined. Periodic observational studies were conducted at 0, 3, 6, and 12 months after delivery of the implant prosthesis. Factors such as implant success rate, marginal bone resorption, periodontal pocket depth, plaque and bleeding index, and prosthetic complications were evaluated, respectively. @*RESULTS@#During the 1-year observation period, all implants survived without functional problems and clinical mobility, showing a 100% implant success rate. Marginal bone resorption was significantly higher in the SCRP group than in the BSRP group only at the time of implant prosthesis delivery (P = .043). In all observation periods, periodontal pocket depth was slightly higher in the BSRP group than in the SCRP group, but there was no significant difference (P > .05). The modified plaque index (mPI) scores of both groups were moderate. Higher ratio of a score 2 in modified sulcus bleeding index (mBI) was observed in the BSRP group in the 6- and 12-months observation. @*CONCLUSION@#Within the limitations of this study, the newly developed zirconia ball- and spring-retained implant prosthesis could be considered as an applicable and predictable treatment method along with the existing screw- and cement-retained prosthesis.

3.
The Journal of Korean Academy of Prosthodontics ; : 119-126, 2022.
Article in English | WPRIM | ID: wpr-918885

ABSTRACT

Mini-implant has been reported as an alternative method to conventional diameter implants in the treatment of mandibular anterior region with narrow ridge. However, one-piece type mini-implant showed biological and technical complications, such as peri-implantitis by residual cement and prosthetic detachment. Recently, one-piece type mini-implant with additional retentive structure has been introduced to increase the retention and stability of the mini-implant. The mini-implant is based on spreading the upper retentive structure with a spreader and connected it with the inner surface of the zirconia prosthesis. In two cases, we tried to reduce these complications through the mini-implant on the narrow mandibular anterior region, and it was possible to reduce the overall treatment period through a digital system. In this case report, restoration using the digital mini-implant system showed improvement of patient satisfaction on the aspect of function and esthetic in the narrow mandibular anterior region.

4.
The Journal of Advanced Prosthodontics ; : 12-21, 2022.
Article in English | WPRIM | ID: wpr-926944

ABSTRACT

PURPOSE@#The purpose of this study was to investigate changes in retention and wear pattern of Locator® and ADD-TOC attachments on a digital milled bar by performing chewing simulation and repeated insertion/removal of prostheses in fully edentulous models. @*MATERIALS AND METHODS@#Locator (Locator®; Zest Anchors Inc., Escondido, CA, USA) was selected as the control group and ADD-TOC (ADDTOC; PNUAdd Co., Ltd., Busan, Republic of Korea) as the experimental group. A CAD-CAM milled bar was mounted on a master model and 3 threaded holes for connecting a bar attachment was formed using a tap. Locator and ADD-TOC attachments were then attached to the milled bar. Simulated mastication and repeated insertion/removal were performed over 400,000 cyclic loadings and 1,080insertions/removals, respectively. Wear patterns on deformed attachment were investigated by field emission scanning electron microscopy. @*RESULTS@#For the ADD-TOC attachments, chewing simulation and repeated insertion/removal resulted in a mean initial retentive force of 24.43 ± 4.89 N, which were significantly lower than that of the Locator attachment, 34.33 ± 8.25 N (P < .05). Amounts of retention loss relative to baseline for the Locator and ADD-TOC attachments were 21.74 ± 7.07 and 8.98 ± 5.76 N (P < .05). @*CONCLUSION@#CAD-CAM milled bar with the ADD-TOC attachment had a lower initial retentive force than the Locator attachment. However, the ADD-TOC attachment might be suitable for long-term use as it showed less deformation and had a higher retentive force after simulated mastication and insertion/removal repetitions.

5.
The Journal of Korean Academy of Prosthodontics ; : 134-141, 2019.
Article in Korean | WPRIM | ID: wpr-742105

ABSTRACT

PURPOSE: The purpose of this study was to compare the clinical outcomes of lithium disilicate ceramic pressed zirconia prostheses and monolithic zirconia prostheses and to investigate the complications after two years of follow-up in posterior edentulous site. MATERIALS AND METHODS: A total 17 patients (male: 12, female: 5) were treated with 60 posterior fixed implant-supported prostheses (LP. lithium disilicate ceramic pressed zirconia prostheses: n = 30, MZ. monolithic zirconia prostheses: n = 30). After 24-month, clinical examination of Implant survival rate, marginal bone resorption, probing depth, plaque index, bleeding index, calculus and complications were evaluated. RESULTS: There were no failed implants and all implants were normal in function without mobility. Marginal bone resorption was lower in LP group than MZ group at 12-month (P < .05), and 12-month probing depth and calculus deposit in LP group were significantly higher than MZ group (P < .05). Most common complications in MZ were marginal bone resorptions more than 1.5.mm and 2 chipping occurred in LP group. CONCLUSION: Within the limitations of the present study, lithium disilicate ceramic pressed zirconia is considered as a predictable treatment option as much as monolithic zirconia in posterior fixed implant-supported prostheses.


Subject(s)
Female , Humans , Bone Resorption , Calculi , Ceramics , Dental Implants , Follow-Up Studies , Hemorrhage , Lithium , Prospective Studies , Prostheses and Implants , Survival Rate
6.
Journal of Korean Dental Science ; : 87-95, 2017.
Article in English | WPRIM | ID: wpr-764770

ABSTRACT

This case study was to report the possible increase in the denture retention and psychological relief using the implant-supported fixed prostheses in a completely edentulous patient. The implants were placed in the anterior portion of the mandible in a patient who had completely edentulous state following the extraction of residual abutment teeth, and consequently a distal extension removable partial denture was fabricated. The patient's adaptation and satisfaction to the new prosthesis was monitored and confirmed in terms of masticatory function and esthetics, by restoring the oral condition similar to initial status before the residual teeth extraction. After 6 months, radiographic examination confirmed that both the abutment teeth and the implants were stable and well maintained. Considering the relatively short clinical follow-up period, however, continuous long-term monitoring was required.


Subject(s)
Humans , Dental Prosthesis, Implant-Supported , Denture Retention , Denture, Partial, Removable , Esthetics , Follow-Up Studies , Mandible , Mandibular Prosthesis , Prostheses and Implants , Tooth
7.
The Journal of Advanced Prosthodontics ; : 341-349, 2017.
Article in English | WPRIM | ID: wpr-31728

ABSTRACT

PURPOSE: This study evaluated the accuracies of different bite registration techniques for implant-fixed prostheses using three dimensional file analysis. MATERIALS AND METHODS: Implant fixtures were placed on the mandibular right second premolar, and the first and second molar in a polyurethane model. Aluwax (A), Pattern Resin (P), and Blu-Mousse (B) were used as the bite registration materials on the healing abutments (H) or temporary abutments (T). The groups were classified into HA, HP, HB, TA, TP, and TB according to each combination. The group using the bite impression coping was the BC group; impression taking and bite registration were performed simultaneously. After impression and bite taking, the scan bodies were connected to the lab analogs of the casts. These casts were scanned using a model scanner. The distances between two reference points in three-dimensional files were measured in each group. One-way ANOVA and Duncan's test were used at the 5% significance level. RESULTS: The smallest distance discrepancy was observed in the TB group using the temporary abutments. The Blu-Mousse and HP groups showed the largest distance discrepancy. The TB and BC groups showed a lower distance discrepancy than the HP group (P=.001), and there was no significant difference between the groups using the temporary abutments and healing abutments (P>.05). CONCLUSION: Although this study has limitations as an in-vitro investigation, the groups using the temporary abutments to hold the Blu-Mousse record and bite impression coping showed greater accuracy than the group using the healing abutments to hold the pattern resin record.


Subject(s)
Bicuspid , Jaw Relation Record , Molar , Pilot Projects , Polyurethanes , Prostheses and Implants
8.
The Journal of Advanced Prosthodontics ; : 244-251, 2017.
Article in English | WPRIM | ID: wpr-114932

ABSTRACT

PURPOSE: The purpose of this study was to determine fracture resistance and failure modes of three-unit fixed dental prostheses (FDPs) made of lithium disilicate pressed on zirconia (LZ), monolithic lithium disilicate (ML), and monolithic zirconia (MZ). MATERIALS AND METHODS: Co-Cr alloy three-unit metal FDPs model with maxillary first premolar and first molar abutments was fabricated. Three different FDPs groups, LZ, ML, and MZ, were prepared (n = 5 per group). The three-unit FDPs designs were identical for all specimens and cemented with resin cement on the prepared metal model. The region of pontic in FDPs was given 50,000 times of cyclic preloading at 2 Hz via dental chewing simulator and received a static load until fracture with universal testing machine fixed at 10°. The fracture resistance and mode of failure were recorded. Statistical analyses were performed using the Kruskal-Wallis test and Mann-Whitney U test with Bonferroni's correction (α=0.05/3=0.017). RESULTS: A significant difference in fracture resistance was found between LZ (4943.87 ± 1243.70 N) and ML (2872.61 ± 658.78 N) groups, as well as between ML and MZ (4948.02 ± 974.51 N) groups (P.05). With regard to fracture pattern, there were three cases of veneer chipping and two interfacial fractures in LZ group, and complete fracture was observed in all the specimens of ML and MZ groups. CONCLUSION: Compared to monolithic lithium disilicate FDPs, monolithic zirconia FDPs and lithium disilicate glass ceramics pressed on zirconia-based FDPs showed superior fracture resistance while they manifested comparable fracture resistances.


Subject(s)
Alloys , Bicuspid , Ceramics , Dental Prosthesis , Denture, Partial, Fixed , Glass , In Vitro Techniques , Lithium , Mastication , Molar , Resin Cements
9.
Journal of Dental Hygiene Science ; (6): 93-100, 2016.
Article in Korean | WPRIM | ID: wpr-656043

ABSTRACT

The purpose of this study was to compare the changes of retentive force in different stud attachment systems for implant retained overdenture. Two commercially available attachments with different retentive forces were investigated: Kerator (pink, blue, red) and O-ring (orange, red). Two implant fixtures were vertically embedded in base mountings. Five pairs of each attachment were evaluated. A universal testing machine was used to evaluate the retentive force of two attachments during wear simulation. Surface characteristics of each attachment system were evaluated with scanning electron microscopy. Five pairs of each attachment were evaluated. Kerator pink showed the highest initial retention. After 2,500 cycles of wear-simulation, Kerator pink noted the largest decrease in retention. According to results of surface analysis, Worn surfaces were obtained in matrices and patrices. Heavy wears were observed in matrices. After 2 year-wear simulation, most attachments exhibited retention loss. Attachments using different kind of material exhibited dissimilar surface alterations.


Subject(s)
Denture, Overlay , Microscopy, Electron, Scanning
10.
The Journal of Advanced Prosthodontics ; : 313-320, 2016.
Article in English | WPRIM | ID: wpr-97837

ABSTRACT

PURPOSE: The aim of this study was to evaluate the clinical findings and patient satisfaction on implant overdenture designed with Locator implant attachment or Locator bar attachment in mandibular edentulous patients. MATERIALS AND METHODS: Implant survival rate, marginal bone loss, probing depth, peri-implant inflammation, bleeding, plaque, calculus, complications, and satisfaction were evaluated on sixteen patients who were treated with mandibular overdenture and have used it for at least 1 year (Locator implant attachment: n=8, Locator bar attachment: n=8). RESULTS: Marginal bone loss, probing depth, plaque index of the Locator bar attachment group were significantly lower than the Locator implant attachment group (P.05). The replacement of the attachment components was the most common complication in both groups. Although there was no correlation between marginal bone loss and plaque index, a significant correlation was found between marginal bone loss and probing depth. CONCLUSION: The Locator bar attachment group indicates lesser marginal bone loss and need for maintenance, as compared with the Locator implant attachment group. This may be due to the splinting effect among implants rather than the types of Locator attachment.


Subject(s)
Humans , Calculi , Denture, Overlay , Dentures , Hemorrhage , Inflammation , Patient Satisfaction , Splints , Survival Rate
SELECTION OF CITATIONS
SEARCH DETAIL